Société Québécoise et Canadienne depuis 1952 !

{"id":4392365752371,"title":"MR1 PULSER 120V","handle":"mr1-pulser-120v","description":"\u003ch3\u003e\u003cstrong\u003eMR1 Pulser\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MR1 Pulser was designed to fit all FillRite, Dresser Wayne 700R, GPI MR 5-30 and GPI QM150 or QM240 meter-registers. The MR1 contains a digital pulse filter, which eliminates overcounting due to vibration.\u003c\/p\u003e\n\u003ch4\u003eFEATURES\u003c\/h4\u003e\n\u003cp\u003e●  Fits ALL variations of the Fill Rite 800 or 900 register!\u003c\/p\u003e\n\u003cp\u003e●  Fits the Dresser Wayne model 700R meter-registers!\u003c\/p\u003e\n\u003cp\u003e●  Fits the new GPI model MR-5-30 Register!\u003c\/p\u003e\n\u003cp\u003e●  10 pulses per gallon output, no configuration required.\u003c\/p\u003e\n\u003cp\u003e●  Digital pulse filtering eliminates overcounts.\u003c\/p\u003e\n\u003cp\u003e●  Simple bolt on installation.\u003c\/p\u003e\n\u003cp\u003e●  Intrinsically safe circuitry, no conduit required!\u003c\/p\u003e\n\u003cp\u003e●  Environmentally coated circuitry eliminates moisture problems.\u003c\/p\u003e\n\u003cp\u003e●  Heavily filtered power supply eliminates noise problems.\u003c\/p\u003e\n\u003cp\u003e●  Extended temperature operation. (-40 to 150 degrees F)\u003c\/p\u003e\n\u003cp\u003e●  12VDC and 110VAC models available.\u003c\/p\u003e\n\u003cp\u003e●  Dual output model available.\u003c\/p\u003e\n\u003cp\u003e●  2 year warranty\u003c\/p\u003e","published_at":"2019-12-09T15:51:19-05:00","created_at":"2019-12-09T15:58:51-05:00","vendor":"EQUIPEMENT GARANT","type":"FLUID INVENTORY CONTROL","tags":["fuel management"],"price":29000,"price_min":29000,"price_max":29000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":31387935014963,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"MR1 PULSER 120V","public_title":null,"options":["Default Title"],"price":29000,"weight":1361,"compare_at_price":null,"inventory_quantity":0,"inventory_management":"shopify","inventory_policy":"continue","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0564\/2397\/products\/MR1-pulser.jpg?v=1575926137","\/\/cdn.shopify.com\/s\/files\/1\/0564\/2397\/products\/MR1-pulser_d8d8fd25-f4ac-4791-85e7-b3ccb76342ff.jpg?v=1575926145"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0564\/2397\/products\/MR1-pulser.jpg?v=1575926137","options":["Title"],"media":[{"alt":null,"id":5811270418483,"position":1,"preview_image":{"aspect_ratio":0.824,"height":595,"width":490,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0564\/2397\/products\/MR1-pulser.jpg?v=1575926137"},"aspect_ratio":0.824,"height":595,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0564\/2397\/products\/MR1-pulser.jpg?v=1575926137","width":490},{"alt":null,"id":5811270713395,"position":2,"preview_image":{"aspect_ratio":0.824,"height":595,"width":490,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0564\/2397\/products\/MR1-pulser_d8d8fd25-f4ac-4791-85e7-b3ccb76342ff.jpg?v=1575926145"},"aspect_ratio":0.824,"height":595,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0564\/2397\/products\/MR1-pulser_d8d8fd25-f4ac-4791-85e7-b3ccb76342ff.jpg?v=1575926145","width":490}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003e\u003cstrong\u003eMR1 Pulser\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MR1 Pulser was designed to fit all FillRite, Dresser Wayne 700R, GPI MR 5-30 and GPI QM150 or QM240 meter-registers. The MR1 contains a digital pulse filter, which eliminates overcounting due to vibration.\u003c\/p\u003e\n\u003ch4\u003eFEATURES\u003c\/h4\u003e\n\u003cp\u003e●  Fits ALL variations of the Fill Rite 800 or 900 register!\u003c\/p\u003e\n\u003cp\u003e●  Fits the Dresser Wayne model 700R meter-registers!\u003c\/p\u003e\n\u003cp\u003e●  Fits the new GPI model MR-5-30 Register!\u003c\/p\u003e\n\u003cp\u003e●  10 pulses per gallon output, no configuration required.\u003c\/p\u003e\n\u003cp\u003e●  Digital pulse filtering eliminates overcounts.\u003c\/p\u003e\n\u003cp\u003e●  Simple bolt on installation.\u003c\/p\u003e\n\u003cp\u003e●  Intrinsically safe circuitry, no conduit required!\u003c\/p\u003e\n\u003cp\u003e●  Environmentally coated circuitry eliminates moisture problems.\u003c\/p\u003e\n\u003cp\u003e●  Heavily filtered power supply eliminates noise problems.\u003c\/p\u003e\n\u003cp\u003e●  Extended temperature operation. (-40 to 150 degrees F)\u003c\/p\u003e\n\u003cp\u003e●  12VDC and 110VAC models available.\u003c\/p\u003e\n\u003cp\u003e●  Dual output model available.\u003c\/p\u003e\n\u003cp\u003e●  2 year warranty\u003c\/p\u003e"}

MR1 PULSER 120V

Description du produit

MR1 Pulser

The MR1 Pulser was designed to fit all FillRite, Dresser Wayne 700R, GPI MR 5-30 and GPI QM150 or QM240 meter-registers. The MR1 contains a digital pulse filter, which eliminates overcounting due to vibration.

FEATURES

●  Fits ALL variations of the Fill Rite 800 or 900 register!

●  Fits the Dresser Wayne model 700R meter-registers!

●  Fits the new GPI model MR-5-30 Register!

●  10 pulses per gallon output, no configuration required.

●  Digital pulse filtering eliminates overcounts.

●  Simple bolt on installation.

●  Intrinsically safe circuitry, no conduit required!

●  Environmentally coated circuitry eliminates moisture problems.

●  Heavily filtered power supply eliminates noise problems.

●  Extended temperature operation. (-40 to 150 degrees F)

●  12VDC and 110VAC models available.

●  Dual output model available.

●  2 year warranty

$290.00
translation missing: fr.products.product.maximum_quantity_error